{"product_id":"membrane-electrode-assembly-electrolytic-cell-two-electrode-system-model-ec-mea2","title":"Membrane Electrode Assembly (MEA) Electrolyzer Cell (Two-Electrode System, Graphite Bipolar Plate Type), Model: EC-MEA2","description":"\u003ch3\u003e\u003cspan\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cstrong\u003eMembrane Electrode Assembly Electrolytic Cells\u003c\/strong\u003e EC-MEA2\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eA general-purpose MEA electrolytic cell with graphite flow fields for configurable reactant distribution and mass-transport research.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe EC-MEA2 is a general-purpose MEA electrolytic cell for CO₂ electroreduction, alkaline anion-exchange-membrane water electrolysis, fuel-cell evaluation and related electrochemical conversion studies. Internal high-purity isostatic graphite plates form the conductive reactant flow fields, while outer titanium fixture plates provide mechanical clamping. Multiple flow-field geometries and sizes support comparative mass-transport, water-management and catalyst-performance studies. Heating and temperature-measurement ports in the outer titanium plates enable controlled-temperature laboratory testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHigh-Purity Graphite Flow-Field Plates\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eHigh-purity isostatic graphite plates provide conductive flow channels for uniform reactant distribution in MEA-based electrochemical testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCustomizable Flow-Field Design\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSupports serpentine, parallel, vein-pattern, spiral, mesh and comb-type channels for mass-transport and water-management studies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLayered Graphite–Titanium Construction\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eInternal graphite flow-field plates are enclosed by outer titanium fixture plates, providing stable mechanical clamping for repeatable MEA assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eChamber structure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-chamber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eElectrode system\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-electrode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnode \/ cathode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSheet-type electrodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlow-field area\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1, 4, 5, 9, 25 cm² (square); customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlow-field size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 × 10, 20 × 20, 22.4 × 22.4, 30 × 30, 50 × 50 mm; customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlow-field configurations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSerpentine, parallel, vein-pattern, etc., customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIndividual plate dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 × 90 × 15 mm; customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlow-field plate material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphite\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFixture plate material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eTypical Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCO₂ Electroreduction\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEvaluating gas-fed MEA performance, graphite flow-field design and cathode water management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAlkaline Water Electrolysis\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eTesting anion-exchange-membrane assemblies with configurable reactant flow fields.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFuel Cell and Catalyst Research\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEvaluating catalyst-coated membranes, sheet-type electrodes and gas-distribution strategies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectrosynthesis and Wastewater Treatment\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eStudying flow-assisted electrochemical conversion and pollutant-removal processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eInstrument Compatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eGas Supply Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompatible with regulated gas-supply systems for controlled delivery of gaseous reactants through the graphite flow fields.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePotentiostat Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompatible with commercial potentiostat for two-electrode MEA testing, including Corrtest Instruments (CS350M).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRelated Published Application\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFlow-Field Water Management in Zero-Gap CO₂ Electrolysis\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eXu et al. compared parallel, serpentine and lizard-inspired graphite cathode flow fields in a custom zero-gap CO₂ electrolyzer with a stainless-steel anode flow field. At 2.25 cm², the lizard-inspired design achieved a CO partial current density of 165.5 mA cm⁻² at 200 mA cm⁻² and maintained approximately 81.3% CO Faradaic efficiency for 24 h. Scale-up to 5.06 cm² was demonstrated at current densities up to 400 mA cm⁻².\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCapabilities Relevant to the EC-MEA2\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDemonstrates MEA operation with configurable graphite cathode flow fields.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompares parallel, serpentine and customized channel geometries.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEvaluates reactant transport, flooding and salt precipitation.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/EC-MEA2_c97e4eba-8b19-4d11-8634-757c8bb66557_480x480.png?v=1792393854\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eOngoing Application Studies\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eApplication studies using this model are currently underway.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cmeta charset=\"UTF-8\"\u003eNote: The referenced study used a custom-made zero-gap CO₂ electrolyzer with graphite cathode flow-field plates and a configuration comparable to the EC-MEA2. It is included solely as a related application example; the article does not identify or use the EC-MEA2 model.\u003c\/span\u003e\u003c\/p\u003e","brand":"Beyond Battery","offers":[{"title":"10 × 10 mm","offer_id":67711805882528,"sku":"CNB-12-EC-MEA2-1","price":3605.0,"currency_code":"SGD","in_stock":true},{"title":"20 × 20 mm","offer_id":67711805915296,"sku":"CNB-12-EC-MEA2-2","price":3605.0,"currency_code":"SGD","in_stock":true},{"title":"5 cm²","offer_id":67711805948064,"sku":"CNB-12-EC-MEA2-3","price":3605.0,"currency_code":"SGD","in_stock":true},{"title":"30 x 30mm (price on request)","offer_id":67711806013600,"sku":"CNB-12-EC-MEA2-4","price":9999.0,"currency_code":"SGD","in_stock":true},{"title":"50 × 50 mm (price on request)","offer_id":67711806046368,"sku":"CNB-12-EC-MEA2-5","price":9999.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/EC-MEA2.png?v=1792393838","url":"https:\/\/beyond-battery.com\/products\/membrane-electrode-assembly-electrolytic-cell-two-electrode-system-model-ec-mea2","provider":"Beyond Battery","version":"1.0","type":"link"}