{"product_id":"in-situ-raman-spectroelectrochemical-cell-model-ec-rm2","title":"In-situ Raman Spectroelectrochemical Cell Model: EC-RM2","description":"\u003ch3\u003e\u003cspan\u003eEC-RM2 In-Situ Raman Spectroelectrochemical Cell\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA two-chamber cell with a replaceable ion-exchange membrane for in-situ Raman monitoring of electrochemical interfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe EC-RM2 provides direct Raman access to a sheet-type working electrode through a quartz optical window while maintaining three-electrode electrochemical control. Its two-chamber, replaceable-membrane design separates the cathode and anode chambers, minimizes anodic interference at the cathode, and supports both syringe filling and external electrolyte circulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eDirect Interface Observation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePositions the working electrode directly below the quartz window for in-situ optical observation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eReplaceable Membrane Separation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSeparates the cathode and anode chambers using a replaceable ion-exchange membrane\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eReduced iR Drop\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePlaces the reference and working electrodes in the same chamber to reduce iR drop\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eWorking electrode area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003e1 cm² (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eWE-optical window distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003e\u0026lt; 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eOptical window diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003eØ37 mm (effective diameter Ø34 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eChamber structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003eTwo-chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eWorking electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003eSheet-type electrode (e.g., Au, Pt, glassy carbon, ITO, FTO, and carbon paper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eReference electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003eAg\/AgCl or Ag\/Ag⁺ electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eCounter electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003ePlatinum wire electrode or graphite rod electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eCell body material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003ePEEK + Ti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eOptical window material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003eQuartz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.626383%;\"\u003e\u003cstrong\u003eCell body dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.300272%;\"\u003eL89 × W70 × H25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/Screenshot_2026-08-13_at_1.47.54_PM_480x480.png?v=1786600511\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" style=\"text-align: start;\"\u003e\n\u003ch3\u003e\u003cspan\u003eInstrument Compatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRaman System Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompatible with commercial Raman microscope systems, including Renishaw (inVia Qontor), HORIBA (LabRAM HR Evolution, iHR550), and Ocean Optical Instruments (HRS-5A)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePotentiostat Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompatible with commercial three-electrode electrochemical workstations, including CH Instruments (CHI660E, CHI760E, CHI1140C), Bio-Logic (VMP3), and Corrtest Instruments (CS350M)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePublished Application Example\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eTwo-Chamber In-situ Raman Monitoring of Methane Electrooxidation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe cell used in this study, supplied by Beyond Battery under product code EC-RM2, a two-chamber cell separated by a Fuma bipolar membrane, was coupled with a LabRAM Soleil microscope to study CH₄ electrooxidation over NiCo hydroxides on carbon cloth. Using 532 nm excitation, in-situ Raman tracked potential-dependent catalyst evolution, oxygen-vacancy-related changes, and CO intermediates associated with CH₃COOH formation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDemonstrated EC-RM2 Capabilities\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBipolar-membrane-separated, two-chamber operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimultaneous Raman and electrochemical measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatibility with carbon-cloth-supported catalysts\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/Screenshot_2026-08-13_at_1.48.29_PM_480x480.png?v=1786600644\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAdditional Published Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eZhu, J. et al. Nat. Commun. 2024, 15, 1565.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLi, Y. et al. Appl. Catal. B Environ. Energy 2024, 357, 124250.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Identification Note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EC-RM2 is the Beyond Battery product code for the same cell reported in the cited publications. The original articles use a different product designation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Beyond Battery","offers":[{"title":"EC-RM2","offer_id":52547592880288,"sku":"CNB-12-EC-RM2","price":3605.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/Screenshot2026-08-13at1.47.25PM.png?v=1786600780","url":"https:\/\/beyond-battery.com\/products\/in-situ-raman-spectroelectrochemical-cell-model-ec-rm2","provider":"Beyond Battery","version":"1.0","type":"link"}