{"product_id":"in-situ-raman-spectroelectrochemical-cell-basic-model-ec-rm1","title":"In-situ Raman Spectroelectrochemical Cell (Basic Model) Model: EC-RM1","description":"\u003ch3\u003e\n\u003cspan\u003eEC-RM1 \u003c\/span\u003e\u003cspan\u003eIn-Situ Raman Spectroelectrochemical Cell\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA compact three-electrode spectroelectrochemical cell for operando Raman monitoring of electrochemical interfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe EC-RM1 provides direct Raman access to a plate-type working electrode through a quartz optical window while maintaining three-electrode electrochemical control. Its compact single-chamber design supports both static electrolyte filling and external electrolyte circulation, making it suitable for mechanistic studies in electrocatalysis, battery materials, and electrochemical interface research.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eDirect Interface Observation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEnables direct optical access to a single electrochemical interface for fundamental reaction studies\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eMinimal System Complexity\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSingle-chamber configuration provides a simplified reaction environment for baseline mechanistic analysis\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInterface Evolution Analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEnables investigation of electrode surface reconstruction and interfacial structural changes during electrochemical operation\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\"\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eWorking electrode area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003e1 cm² (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eWE-optical window distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003e\u0026lt; 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eOptical window diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003eØ37 mm (effective diameter Ø34 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eChamber structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003eSingle-chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eWorking electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003ePlate-type electrodes (e.g., Au, Pt, glassy carbon, ITO, FTO, and carbon paper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eReference electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003eAg\/AgCl or Ag\/Ag⁺ electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eCounter electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003ePlatinum wire electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eCell body material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003ePEEK + Ti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eOptical window material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003eQuartz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.186981%;\"\u003e\u003cstrong\u003eCell body dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.739674%;\"\u003eL70 × W70 × H19 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" style=\"text-align: start;\"\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/EC-RM1_480x480.png?v=1786614405\" style=\"float: none;\"\u003e\u003cbr\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eInstrument Compatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eRaman System Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompatible with commercial Raman microscope systems, including Renishaw (inVia Qontor), HORIBA (LabRAM HR Evolution, iHR550), and Ocean Optical Instruments (HRS-5A)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePotentiostat Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompatible with commercial three-electrode electrochemical workstations, including CH Instruments (CHI660E, CHI760E, CHI1140C), Bio-Logic (VMP3), and Corrtest Instruments (CS350M)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePublished Application Example\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eIn-situ Raman Monitoring of Glycerol Electrooxidation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe cell used in this study, supplied by Beyond Battery under product code EC-RM1, was coupled with an HRS-5A Raman spectrometer to investigate an Au₁Cu₁–Ag\/AgBr catalyst supported on carbon paper. Its single-compartment, three-electrode configuration enabled time-resolved Raman acquisition directly from the working electrode under an applied potential of 1.43 V. Raman changes near 1060 and 1400 cm⁻¹ were monitored during electrolysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDemonstrated EC-RM1 Capabilities\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSimultaneous Raman and electrochemical measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuous monitoring under an applied potential\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatibility with catalyst-coated carbon paper\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAdditional Published Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eChen, W. et al. ACS Sustainable Chem. Eng. 2025, 13, 11607–11616.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLv, H. et al. Nat. Commun. 2023, 14, 3117.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/EC-RM1_0b1d2bba-2096-4ed9-912c-5eb8fb6b8c75_480x480.png?v=1786614406\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Identification Note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EC-RM1 is the Beyond Battery product code for the same cell reported in the cited publications. The original articles use a different product designation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Beyond Battery","offers":[{"title":"EC-RM1","offer_id":52547460497568,"sku":"CNB-12-EC-RM1","price":2563.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/EC-RM1_04a07696-779d-4ce6-8c78-bced38b36a75.png?v=1786614756","url":"https:\/\/beyond-battery.com\/products\/in-situ-raman-spectroelectrochemical-cell-basic-model-ec-rm1","provider":"Beyond Battery","version":"1.0","type":"link"}