{"product_id":"modular-in-situ-electrochemical-cell-model-ec-mod","title":"Modular In-situ Electrochemical Cell Model: EC-MOD","description":"\u003ch3\u003e\n\u003cspan\u003eEC-MOD \u003c\/span\u003e\u003cspan\u003eModular In-situ Electrochemical Cell\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA modular, multifunctional flow cell for in-situ UV, Raman, IR, XAFS, and XRD studies under controlled electrochemical conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe EC-MOD is a modular flow-through electrochemical cell designed to couple three-electrode control with in-situ spectroscopy and diffraction. Interchangeable optical and X-ray window assemblies configure the same base cell for Raman, UV, IR, XAFS, or XRD measurements. Standard plate-electrode, and gas-diffusion configurations support liquid-phase interfacial studies, spectroelectrochemical analysis, and gas-fed electrocatalytic reactions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMulti-technique Window Platform\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eInterchangeable quartz, sapphire, CaF₂, Kapton-film and beryllium windows configure the cell for different in-situ analytical methods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDual Working Electrode Configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eStandard plate-electrode and gas-diffusion assemblies support conventional liquid-phase studies and gas-fed electrocatalysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFlow-Through Electrolyte Circulation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eDedicated inlet and outlet ports support external electrolyte circulation and controlled flow during electrochemical measurements.\u003cbr\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eWE-optical window distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003e\u0026lt; 1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eOptical window size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003e15 × 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eChamber structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003eSingle-chamber (standard configuration); Two-chamber (gas-diffusion configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eWorking electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003eSheet-type electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eReference electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003eAg\/AgCl electrode (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eCounter electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003ePlatinum wire electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eCell body material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003ePEEK + Ti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eRaman\/UV windows\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003eSapphire (standard) or quartz (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eXAFS window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003eKapton film (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eXRD window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003eBeryllium (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.908002%;\"\u003e\u003cstrong\u003eIR window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.028168%;\"\u003eCaF₂ (ZnSe optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cspan\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIn-situ Raman\/UV Measurements\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eMonitoring interfacial species and reaction intermediates\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIn-situ IR Measurements\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eMonitoring adsorbed species and reaction pathways\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIn-situ XAFS Measurements\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eProbing oxidation states and coordination structures\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIn-situ XRD Measurements\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eTracking phase and structural evolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGas-Diffusion Electrode Studies\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSuitable for CO₂RR, ORR, and NRR\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eInstrument Compatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSpectroscopy and X-ray Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eConfigurable for Raman, UV, and IR optical systems, synchrotron XAFS beamlines, and laboratory or synchrotron XRD instruments, subject to instrument geometry, beam size, incidence angle, optical access, and working-distance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectrochemical and Flow System Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompatible with standard three-electrode potentiostats, external electrolyte pumps, PTFE tubing, gas-supply systems and downstream product-collection equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStandard and Gas-Diffusion Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eStandard Configuration (single-chamber)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/Screenshot2026-08-17at5.14.53PM_240x240.png?v=1786958589\" alt=\"\" style=\"float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/Screenshot_2026-08-17_at_5.15.05_PM_240x240.png?v=1786958653\" style=\"margin-bottom: 16px; float: none;\"\u003e\n\u003c\/div\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGas-diffusion Configuration (two-chamber)\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/Screenshot2026-08-17at5.15.37PM_480x480.png?v=1786958591\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eApplication Studies\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eApplication studies using this model are currently underway.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Beyond Battery","offers":[{"title":"EC-MOD","offer_id":52891005124768,"sku":"CNB-12-EC-MOD","price":2881.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/EC-RM4.png?v=1786957177","url":"https:\/\/beyond-battery.com\/en-us\/products\/modular-in-situ-electrochemical-cell-model-ec-mod","provider":"Beyond Battery","version":"1.0","type":"link"}