{"product_id":"gas-diffusion-electrochemical-cell-solid-electrolyte-series-model-ec-gde-se-series","title":"Gas Diffusion Electrochemical Cell (Solid-Electrolyte Series), Model: EC-GDE-SE Series","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eEC-GDE-SE Series \u003cstrong\u003eGas Diffusion Electrochemical Cell\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eA three-chamber solid-electrolyte cell series for high-purity liquid production, potential studies, flow-field development, and optical observation.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EC-GDE-SE Series comprises four three-chamber solid-electrolyte electrochemical cells for high-purity aqueous liquid-product generation. Their sandwich architecture combines gas-fed electrode chambers, ion-exchange membranes and a central solid-electrolyte chamber, where ionic products recombine and are collected by flowing pure water. Available configurations support two- or three-electrode measurements, central flow-field development, optical observation, and photo-assisted reaction studies.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-Electrolyte Product Recovery\u003c\/strong\u003e\u003cbr\u003eA pure-water stream collects high-purity aqueous products from the central solid-electrolyte chamber with minimal electrolyte contamination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree-Chamber Gas-Solid Architecture\u003c\/strong\u003e\u003cbr\u003eGas-fed chambers, ion-exchange membranes, and catalyst-loaded gas-diffusion layers create controlled gas-solid reaction interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch-Specific Configurations\u003c\/strong\u003e\u003cbr\u003eModels support two- or three-electrode testing, central flow-field development, optical observation, and photo-assisted reactions.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Purity Liquid-Product Generation\u003c\/strong\u003e\u003cbr\u003eHigh-purity aqueous product collection for solid-electrolyte electrolysis research.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrode-Potential \u0026amp; Mechanistic Studies\u003c\/strong\u003e\u003cbr\u003eThree-electrode measurements for catalyst evaluation and reaction-mechanism studies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlow-Field Development \u0026amp; Mass-Transfer Studies\u003c\/strong\u003e\u003cbr\u003eCentral flow-field design for mass-transfer analysis and device optimization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn Situ Optical \u0026amp; Photo-Assisted Studies\u003c\/strong\u003e\u003cbr\u003eOptical access for in situ observation, photocatalysis, and photoelectrochemical studies.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003cbr\u003e\u003cmeta charset=\"UTF-8\"\u003e\n\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 29.24968%;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"width: 69.68649%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eChamber structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eThree-chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eElectrode system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eTwo-electrode (QG-20-1, -3 and -4); three-electrode (QG-20-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eAnode-cathode gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eActive area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003e4 cm² (20 x 20 mm, customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eAnode and cathode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eSheet-type gas diffusion electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eReference electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eRod-type electrode (QG-20-2 only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eCentral-chamber design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eOpen chamber (QG-20-1 and -2); serpentine flow field (QG-20-3 and -4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eCell body material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eTi + PEEK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eGas flow field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eSerpentine (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.24968%;\"\u003e\u003cstrong\u003eOptical window material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.68649%;\"\u003eQuartz (QG-20-4 only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eModel Selection Guide\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQG-20-1\u003c\/strong\u003e\u003cbr\u003eThe standard configuration for high-purity liquid-product generation and routine solid-electrolyte research. Its two-electrode design and open central chamber are suitable for electrolyte evaluation and device testing.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/QG-20-1_480x480.png?v=1788507237\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eQG-20-2\u003c\/strong\u003e\u003cbr\u003eFor experiments requiring individual electrode-potential monitoring. A dedicated reference-electrode chamber enables three-electrode measurements for catalyst evaluation and mechanistic studies.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/QG-20-2_480x480.png?v=1788507237\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eQG-20-3\u003c\/strong\u003e\u003cbr\u003eFor flow-field development and mass-transfer studies. A serpentine flow field in the central chamber supports device optimization and technology validation.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/QG-20-3_480x480.png?v=1788507237\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eQG-20-4\u003c\/strong\u003e\u003cbr\u003eFor experiments requiring optical access to the cathode chamber. It combines a central serpentine flow field with a high-transmittance quartz window for in situ observation, photocatalytic studies, and photoelectrochemical experiments.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/QG-20-4_480x480.png?v=1788507237\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003ch3\u003eRelated Published Application\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Efficiency H₂O₂ Electrosynthesis in a Solid-Electrolyte Cell\u003c\/strong\u003e\u003cbr\u003eDong et al. used a two-electrode, three-chamber solid-electrolyte flow cell to investigate direct H₂O₂ electrosynthesis via O₂ reduction. At 2.5 V, the system operated at approximately 100 mA cm⁻² for 8 h, producing a 3400 ppm H₂O₂ solution with approximately 85% Faradaic efficiency.\u003c\/p\u003e\n\u003ch3\u003eCapabilities Relevant to the QG-20 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeparates anode, solid-electrolyte, and cathode regions with ion-exchange membranes for selective ion transport.\u003c\/li\u003e\n\u003cli\u003eCollects central-chamber aqueous products directly via a flowing pure-water stream.\u003c\/li\u003e\n\u003cli\u003eSupports continuous electrolysis with gas-flow channels and central water flow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Studies\u003c\/h3\u003e\n\u003cp\u003eApplication studies using this model are currently underway.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/QG-20_480x480.png?v=1788507237\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eNote: The referenced study used a two-electrode, three-chamber solid-electrolyte cell with a configuration comparable to the QG-20 Series. It is included solely as a related application example and does not confirm that any QG-20 Series model was used.\u003c\/em\u003e\u003c\/p\u003e","brand":"Beyond Battery","offers":[{"title":"EC-GDE-SE1","offer_id":58768344088736,"sku":"CNB-12-EC-GDE-SE1","price":2653.0,"currency_code":"USD","in_stock":true},{"title":"EC-GDE-SE2","offer_id":58768344121504,"sku":"CNB-12-EC-GDE-SE2","price":2888.0,"currency_code":"USD","in_stock":true},{"title":"EC-GDE-SE3","offer_id":58839016669344,"sku":"CNB-12-EC-GDE-SE3","price":2905.0,"currency_code":"USD","in_stock":true},{"title":"EC-GDE-SE4","offer_id":58839016702112,"sku":"CNB-12-EC-GDE-SE4","price":3324.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/5705\/2832\/files\/QG-20-1.png?v=1788507237","url":"https:\/\/beyond-battery.com\/en-us\/products\/gas-diffusion-electrochemical-cell-solid-electrolyte-series-model-ec-gde-se-series","provider":"Beyond Battery","version":"1.0","type":"link"}